PROJECTS
We’ve worked on some great projects over the years
A majority of our fire sprinkler installation and maintenance contracts have been in and around London but we cover the whole of the United Kingdom.
Here is a selection of our domestic and residential projects, past and ongoing.
VALIANT HOUSE
STATUS
Complete
LOCATION
Charlton, London
POST CODE
SE7
This 17 storey block consisting 93 1 & 2 bedroom flats was constructed in the 1970’s and is located in Charlton,
overlooking Charlton Athletic Football Club.
Due to the height of the building it was decided that a sprinkler system should be retroactively installed as additional protection for the residents.
The system installed complies with and meets the requirements of BS9251:2014 for a category 2 system, this is fed via a dedicated pump and tank located with the ground floor plant area. Each level is fitted with a flow switch to provide a fire signal if the system is activated, plus the alarm panel receiving the signal will indicate the level on which the sprinkler system activated.
The installation itself was carried out while upgrade works were undertaken to minimise disruption to the tenants and allow for cost savings, such as sharing a fixed scaffold and welfare facilities.
We carried out the entire retro fit installation, including all concealment works ensuring the clients requirements were met at all times.
980
HEADS INSTALLED
LAKEVIEW COURT
STATUS
Complete
LOCATION
Thamesmead, London
POST CODE
SE28
This extra care housing block has 58 1 & 2 bedroom flats, it was constructed in 2010 to comply with the lifetime homes model
and is located in Thamesmead central.
As well as self-contained flats the building has several communal areas including dining areas for extra support.
Due to the vulnerability of the residents it was decided that a sprinkler system should be retro fitted to the property as an enhancement to the existing life safety systems already in place.
The sprinkler system installed complies with the requirements of BS9251:2014 category 3 and utilises the existing cold water boosted system as a feed to the sprinklers. Each level is fitted with a flow switch to provide a fire signal if the system is activated, plus the alarm panel receiving the signal will indicate the level on which the sprinkler system activated.
We carried out the entire retro fit installation, including all concealment works ensuring all the clients requirements were met.
600
HEADS INSTALLED
BREWSTER HOUSE
STATUS
Complete
LOCATION
Bermondsey, London
POST CODE
SE1
This social housing scheme consists of 23 1 bedroom flats and
is located in Bermondsey
Due to the vulnerability of the residents it was decided that a sprinkler system should be retro fitted to the property as an enhancement to the existing life safety systems already in place.
The system installed complies with and meets the requirements of BS9251:2014 for a category 3 system, this is fed via a dedicated pump and tank located within the back garden.
Each level is fitted with a flow switch to provide a fire signal if the system is activated, plus the alarm panel receiving the signal will indicate the level on which the sprinkler system activated.
We carried out the entire retro fit installation, including all concealment works ensuring all the clients requirements were met.
232
HEADS INSTALLED
THE ROYAL BELL HOTEL
STATUS
Complete
LOCATION
Bromley, Kent
POST CODE
BR1
This local landmark has its origins in the 16th century and by
the 18th century it was one of Bromley’s busiest coaching inns.
In 1898 the building was completely rebuilt as a new luxury hotel.
The Royal Bell has recently been refurbished and part of this refurbishment was
the requirement to install sprinkler protection to meet building regulation approval.
The system installed complies with and meets the requirements of BS9251:2014 for a category 3 system, this is fed via a dedicated pump and tank located within the basement plant area.
Each level is fitted with a flow switch to provide a fire signal if the system is activated, plus the alarm panel receiving the signal will indicate the level on which the sprinkler system activated.
37
HEADS INSTALLED
LANCASTER COURT
STATUS
Complete
LOCATION
Forest Gate, London
POST CODE
E7
This social housing scheme consists of 24 1 & 2 bedroom flats,
the property is located within Forest Gate.
Due to the vulnerability of the residents it was decided that a sprinkler system should be retro fitted to the property as an enhancement to the existing life safety systems already in place.
The system installed complies with and meets the requirements of BS9251:2014 for a category 3 system, this is fed via a dedicated pump and tank located within the back garden.
Each level is fitted with a flow switch to provide a fire signal if the system is activated, plus the alarm panel receiving the signal will indicate the level on which the sprinkler system activated.
We carried out the entire retro fit installation, including all concealment works ensuring all the clients requirements were met.
156
HEADS INSTALLED
DOMENEY COURT
STATUS
In Progress
LOCATION
Forest Gate, London
POST CODE
E7
This old monastery was refurbished in 1995 to house retired
persons. This social housing scheme consists of 24 1 & 2
bedroom flats and is located in Forest Gate.
Due to the vulnerability of the residents, plus the age of the building, it was decided that a sprinkler system should be installed.
The building itself is listed and requires approvals for most types of work undertaken within and around the building.
We are currently working closely with a specialist Architect to ensure the proposed BS9251, category 3 system will meet both the requirements of the sprinkler standard and gain approval from the local authority.